Product Description
The split water pump control panel is an intelligent and economical system designed for pumps and motors,can be encased to constitute the whole controller set.Pump Control Panel that start and stop pumps and devices that allow operator monitoring and control. Suitable for Surface pump,Sewage Pump,Booster pump,Submersible pumps and etc.
Typical application scenarios:
-Agricultural irrigation/ pumping
-Pressure Booster Systems
-Waste water treatment
-Water Tanks/Wells
-Drainage System
-Cooling Towers
-Flood Control
-Fishing Boat
Specifications of water pump controller
Type | D1F | |||||
Model | D1F-11000 | D1F-30000 | ||||
Rated Power | 0.75-11KW | 11-30KW | ||||
Rated Input Voltage | 380+10%/50Hz or 60Hz | |||||
Qty.of Controlled Pump | Single pump | |||||
Display | LCD display | |||||
Signal Transmission Mode | Level float switch Level probe Pressure switch Electric contact pressure gauge |
|||||
Water Level Indication | High/Middle/Low | |||||
Max.Control Distance | ≤2000m without strong electric and electromagnetic fields | |||||
Over/under-voltage Range | 304V-456V(adjustable) | |||||
Protections | Pump stalled protection Dry run protection Over-load protection Under-voltage protection Over-voltage protection Open phase protection Short circuit protection |
|||||
Main Functions | Time setting Fault detection Anti-rust inspection Automatic restart after power recovery |
|||||
Product Size | 170x120x50mm | |||||
Working temperature Working humidity Degree of protection Install position |
-25ºC-- +55ºC 20%--90%RH, no drips concreted IP22 Wall mounting |
Parameter Setting and Instruction
P01--Over-load protection current setting
P02--No-load protection current setting
P03--Time setting ON
P04--Time Setting OFF
P05--Restart time setting after no-load protection
P07--Over-voltage protection setting
P08--Under-voltage protection setting
P09--LCD backlight OFF time setting
1)How to convert HP into KW ?
The conversion formula as :1HP=0.74KW
for example: 3HP=3x0.74KW=2.22KW.
2)How to choose the power of your pump controller?
Normally we need choose bigger power to run the water pump or motors,.If the pump rated power is 4KW,Pump controller should choose 7.5KW.For Submersible pumps which used in the deep well,please check with us first .
3)Can I have the samples of your pump controller ?
Yes, we can send you the pump controller samples for your testing .
4)Can you provide OEM or ODM ?
Yes,we can make the orders according to your detailed request.
5)what is your delivery time?
It takes 3-5 days for sample orders,and 15-20 days for orders