Product Description
D2F water pump control boards are designed to control two pumps DOL either tank filling or emptying in clean or waste water applications.They provide pump protection with self learning of pump operating data during initial setup as well as settable parameters, including run dry failure and monitoring of power supply and motor limits, overload protection.
Typical application scenarios:
-Agricultural irrigation/ pumping
-Pressure Booster Systems
-Waste water treatment
-Water Tanks/Wells
-Drainage System
-Cooling Towers
-Flood Control
-Fishing Boat
Specifications of water pump controller
Type | D2F | |||||
Model | D2F-11000 | D2F-18500 | ||||
Rated Power | 0.75-11KW | 18.5KW | ||||
Rated Input Voltage | 380+10%/50Hz or 60Hz | |||||
Qty.of Controlled Pump | Dual pumps | |||||
Display | LCD display | |||||
Signal Transmission Mode | Level float switch Level probe Pressure switch Electric contact pressure gauge | |||||
Water Level Indication | High/Middle/Low | |||||
Max.Control Distance | ≤2000m without strong electric and electromagnetic fields | |||||
Over/under-voltage Range | 304V-456V(adjustable) | |||||
Protections | Pump stalled protection Dry run protection Over-load protection Under-voltage protection Over-voltage protection Open phase protection Short circuit protection | |||||
Main Functions | Time setting Fault detection Anti-rust inspection Automatic restart after power recovery | |||||
Product Size | 170x120x50mm | |||||
Working temperature Working humidity Degree of protection Install position | -25ºC-- +55ºC 20%--90%RH, no drips concreted IP22 Wall mounting |
Parameter Setting and Instruction
P01--Over-load protection current setting
P02--No-load protection current setting
P03--Time setting ON
P04--Time Setting OFF
P05--Restart time setting after no-load protection
P06--Dual pump alternation time setting
P07--Over-voltage protection setting
P08--Under-voltage protection setting
P09--LCD backlight OFF time setting
Dual Pump Operation Mode
One duty one standby
Dual pump alternation in shifts
Automatic dual pump mutual exchange in faults
Dual pump simultaneous start
1)How to convert HP into KW ?
The conversion formula as :1HP=0.74KW
for example: 3HP=3x0.74KW=2.22KW.
2)Can you provide OEM or ODM ?
Yes,we can make the orders according to your detailed request.
3)what is your delivery time?
It takes 3-5 days for sample orders,and 15-20 days for orders