This browser does not support the video element.
Product Description of Duplex Pump Control Panel
The ABS control panel is a direct on-line and pump controller to be used on three phase dual pump control system.It is able to control up to two pumps and balance the load between them by alternating the starts of each pump,two pumps can also be activated at the same time.It also allows users read last 10 faults of the pump,help diagnose for pump repair and maintenance.
Typical application of Duplex Pump Control Panel
-Agricultural irrigation/ pumping
-Pressure Booster Systems
-Waste water treatment
-Sewage pump station
-Water Tanks/Wells
-Drainage System
-Cooling Towers
-Flood Control
-Fishing Boat
Specifications of Duplex Pump Control Panel
General Specification | ||||
Type | Y2 | |||
Model | Y2-4KW | Y2-7.5KW | Y2-11KW | Y2-15KW |
Rated Power | 0.75-4KW | 1.1-7.5KW | 1.1-11KW | 2.2-15KW |
Rated Input Voltage | 380+10%/50Hz or 60Hz | |||
Qty.of Controlled Pumps | Dual pumps | |||
Display | LCD display | |||
Signal Transmission Mode | Level float switch Level probe Pressure switch Electric contact pressure gauge |
|||
Water Level Indication | High/Middle/Low | |||
Max.Control Distance | ≤2000m without strong electric and electromagnetic fields | |||
Over/under-voltage Range | 304V-456V(adjustable) | |||
Protections | Pump stalled protection Dry run protection Over-load protection Under-voltage protection Over-voltage protection Open phase protection Short circuit protection |
|||
Main Functions | Time setting Fault detection Anti-rust inspection Dual pump rotation Automatic restart after power recovery |
|||
Working temperature Working humidity Degree of protection Install position |
-25ºC-- +55ºC 20%--90%RH, no drips concreted IP54 Wall mounting |
|||
Product Size | 220x330x135mm | |||
Package | Box size:26.2*17.2*38cm Carton size:54*39.5*55.5cm PCS/CTN:6 |
1)How to convert HP into KW ?
The conversion formula as :1HP=0.74KW
for example: 3HP=3x0.74HP=2.22KW.
2)How to choose the power of your pump controller?
Normally we need choose bigger power to run the water pump or motors,.If the pump rated power is 4KW,Pump controller should choose 7.5KW.For Submersible pumps which used in the deep well,please check with us first .
3)Can I have the samples of your pump controller ?
Yes, we can send you the pump controller samples for your testing .
4)Can you provide OEM or ODM ?
Yes,we can make the orders according to your detailed request.
5)what is your delivery time?
It takes 3-5 days for sample orders,and 15-20 days for orders